Specifications
Product code | Key Characteristics | Application |
Rocare A11 | Neutral pH Antiscalant | 1000 ppm Hardness, 50 ppm Silica |
Rocare A21 | Broad Spectrum Antiscalant | LSI upto 2.5, 160 ppm Silica |
Rocare A31 | Premium Antiscalant | LSI upto 3, 400 ppm Silica |
ROCARE A31
Premium Membrane Antiscalant
DESCRIPTION:
ROCARE A31 is a premium broad spectrum antiscalant comprising of synergistic blend of specialized dispersants and scale inhibitors for Reverse Osmosis Membrane.
BENEFITS:
TYPICAL PROPERTIES:
Appearance : Clear, colourless to yellow liquid
Odor : Characteristic Odour
pH (as is) @ 250C : ≤ 2
Specific Gravity : 1.15 ± 0.05
Water Solubility : Completely soluble
APPLICATION:
ROCARE A31 is normally fed continuously prior to the final cartridge filter. It should be injected by chemical dosing pump from a dilution tank or directly from the drum to the feedwater line.
Recommended minimum dosage is 2 to 5 ppm and to maximum of 10 to 12 ppm , subject to inlet water quality in respect of TDS , Calcium and Silica.
Please use acid compatible materials for chemical tanks , pump and piping.
ROCARE A21
Broad Spectrum Membrane Antiscalant
DESCRIPTION:
ROCARE A21 is a broad spectrum antiscalant comprising of blend of dispersants and scale inhibitors for Reverse Osmosis Membrane effectively controlling deposition of inorganic scales.
BENEFITS:
TYPICAL PROPERTIES:
Appearance : Clear, yellow to amber liquid
Odour : Characteristic odour
pH (as is) @ 250C : ≤ 2
Specific Gravity : 1.15 ± 0.05
Water Solubility : Completely soluble
APPLICATION:
ROCARE A21 is normally fed continuously prior to the final cartridge filter. It should be injected by chemical dosing pump from a dilution tank or directly from the drum to the feed water line.
Recommended minimum dosage is 3 to 6 ppm and to maximum of 10 to 12 ppm , subject to inlet water quality in respect of TDS , Calcium and Silica.
Please use acid compatible materials for chemical tanks , pump and piping.
ROCARE A11
Neutral pH Membrane Antiscalant
DESCRIPTION:
ROCARE A11 is a synergistic blend of neutral pH scale modifiers and dispersants to be used as antiscalant for Reverse Osmosis Membrane effectively controlling deposition of inorganic scales.
BENEFITS:
TYPICAL PROPERTIES:
Appearance : Clear, colourless to pale yellow liquid
Odour : Characteristic odour
pH Undiluted : 7 ± 1
Specific Gravity : 1.15 ± 0.05
Water Solubility : Completely soluble
APPLICATION:
ROCARE A11 is normally fed continuously prior to the final cartridge filter. It should be injected by chemical dosing pump from a dilution tank or directly from the drum to the feed water line.
Recommended minimum dosage is 3 to 6 ppm and to maximum of 10 to 12 ppm , subject to inlet water quality in respect of TDS , Calcium and Silica.
ROCARE B41
Non Oxidizing Membrane Biocide
DESCRIPTION:
ROCARE B41 is a fast acting, non oxidizing biocide. It is environmental friendly as it is non persistent and degrades to naturally occurring products. It provides efficient and cost effective microbiological control.
BENEFITS:
TYPICAL PROPERTIES:
Appearance : Clear to pale yellow liquid
Odor : Characteristic mild pungent odour
pH Undiluted : 3.0 – 5.0
Specific Gravity : 1.15 ± 0.05
Water Solubility : Completely soluble.
APPLICATION:
ROCARE B41 should be added to system inlet water or before any other contamination area ahead of the reverse osmosis unit. ROCARE B41 should be added with a metering pump on an intermittent basis depending on the severity of contamination and the guidelines specified by the membrane manufacturer.
ROCARE B41 may be fed continuously to the membrane system feed water at the rate of 10 to 100 ppm. Once treatment is completed, rinsing with feed water should continue until conductivity values in permeate are at or below values before treatment with ROCARE B41. Badly fouled systems must be cleaned before treatment is begun.
For off-line system disinfection, add 50-170 ppm ROCARE B41 to the off-line cleaning feed tank and re-circulate for 30 minutes to 3 hours. Frequency of addition should be every 5 days or as needed.
During and for 30 for minutes to 1 hour following chemical addition, permeate and concentrate streams must be diverted to waste.
Please use acid compatible materials for chemical tanks , pump and piping.